AC blowing warm air: what to check before you call

“It’s on and it’s blowing, but it’s not cold.” That sentence is most of our summer phone calls. A lot of those visits end at a thermostat, a filter, or an outdoor unit that never started.

Do these in order

  1. Mode and setpoint. Cool, not Off. Setpoint about 3° below the room. Fan Auto, not On — On will blow room air and fool you.
  2. Filter. Light test. A packed filter ices the indoor coil. Ice makes warm air. Replace the filter, thaw (Cool Off, fan On), then try again. If it ices the same day, stop.
  3. Outdoor unit. Is the fan spinning while the thermostat is calling? Silent and still is usually power, a capacitor, or a contactor — not a hose-and-hope.
  4. Split. After ten minutes, the vent should feel clearly colder than the hallway. If you have a kitchen thermometer, supply vs return is the adult version. Under about 8° of difference while running is a fault.

The Toolbox is those gates with Skip if you do not want to crawl around. It is not a diagnosis. It is so we are not starting from zero.

Stop and call

Burning smell, gas smell, smoke. A breaker that trips again after one reset. Standing water at the air handler. Those are not filter day.